GPC-1000

Sales

GS Customer Support

Features & Benefits

  • Supports Triplex, Dual and Simplex flight control architectures
  • Supports single or multiple servo-control channels per GPC-1000
  • Contains a CPU that supports communication with all installed INS/GPS and its designated servo-control channels
  • CPU also supports any voting functions allocated to the unit in the target architecture

Specifications

Performance specs

Performance Specs

Size

16 x 13 x 7.6 cm (6.3 x 5.1 x 3 in)

Weight

0.91 kg (2.0 lbs)

Update rate

Servo update rate ³ 50 Hz

Flash memory

Capable of supporting 512 MB

Enclosure

Aluminum

Power

£ 8 W @ 28 VDC under nominal conditions; no loads

Differential analog inputs

8 Differential analog inputs

The analog inputs support voltage levels of -9.02 VDC to + 10 VDC

Configurable to support analog input voltage ranges within the maximum -9.02 V to + 10 V range on a per channel basis

The analog inputs are converted with a resolution of minimum 11 bits

General purpose discrete inputs

Up to 16 General purpose discrete inputs

Supports pulse-width modulated (PWM) operation

28 V tolerant

Default low or default high; configurable at the time of PCA manufacture

VIL £ 0.8 VDC

VIH ³ 3.5 VDC

5 V or 28 V nominal; input voltage levels are configurable at the time of PCA manufacture

Dedicated discrete inputs

6 Dedicated discrete inputs support two UID bits, one SW_EN bit, and three health bits

Supports VIL £ 0.8 VDC

Supports VIH ³ 3.5 VDC

Differential discrete inputs

1 Discrete input driven at RS-422 levels, 2 pins

Supports PWM operation

Analog outputs

1analog output

Voltage range is -10 V to + 10 V (configurable ranges)

Current capability is £ 20 mA

Reference voltage output for analog inputs

1 analog reference voltage output

General purpose discrete outputs

Up to 14 General purpose discrete outputs

Outputs are individually selectable, via jumpers at the time of PCA manufacture, to supply either 5 VDC, or 28 VDC nominal

VOL £ 0.8 VDC unloaded; £ 1.5 V with 200 mA load

VOH ³ 3.5 VDC when the 5 V strapping option is selected

VOH ³ 16.0 VDC when the 28 V strapping option is selected

Each of the 11 outputs are capable of PWM operation

Each of the 11 outputs are driven by a tri-state device, individually controlled by hardware logic

Health bit discrete outputs

3 Discrete outputs dedicated for the output of unit health bit information.

Provide VIL £ 0.8 VDC

Provide VOH 3.5 ³ VDC for 5 VDC output operation or VOH ³ 16 VDC for 28 VDC output operation

Discrete RS-422 level outputs

2 RS-422 level discrete outputs, 2 pins each

Each of the discrete RS-422 level outputs are capable of PWM operation

Each of the 2 discrete RS-422 level outputs are driven by a tri-state device, individually controlled by hardware logic

RS-232 only port

1 Serial port that supports the RS-232 standard only; (2 pins)

RS-232/422/485 serial ports

3 General purpose serial I/O channels that can be each be strapped via hardware jumpers at the time of PCA manufacture to support either the RS-232, RS-422, or RS-485 (2 or 4 wire) serial communication standard

RS-422/485 serial ports

5 General purpose serial I/O channels that can be each be strapped via hardware jumpers at the time of PCA manufacture to support either the RS-422 or RS-485 (2 or 4 wire) serial communication standard

Serial input / output

Serial ports configured for RS-232 operations operate at rates up to 115.2 kb/s

Serial ports configured for RS-422 or RS-485 operate at rates up to 921.6 kb/s

Outputs of 8 of the 9 serial ports are driven by a tri-state device, individually controlled by hardware logic

CAN Bus

2 CAN 2.0 A serial I/O channel, 2 pins each

Provides the option for installation of a CAN bus termination resistor at the time of PCA manufacture

Outputs of the CAN bus are driven by a tri-state device, controlled by hardware logic

Ethernet

Supports one 10/100 BASE-T interface connecting the bulkhead connector to the processor for maintenance and PPP communication; 4 pins.

Power

Input voltage (nominal)28 VDC
Steady-state voltage tolerance18.0 V to 32.2 V
Ripple tolerance (200 Hz to 1 kHz)
(1 kHz to 15 kHz)
>= 0.56 VRMS
>= 1.4 VRMS
Current consumption (under nominal conditions; no loads)<= 290 mA
Power consumption (under nominal conditions; no loads)4.5 W
Momentary power interruption<= 50 ms

Typical System

Main Components

Model number

Comments

822-2958-005

Refer to User’s Manual 523-0020182-001. The unit has up to 15 general-purpose inputs, up to 4 analog outputs, up to 14 general purpose discrete outputs, 1 serial port that supports RS-232 and 4 general purpose serial I/O channels that can each be strapped via hardware jumpers at the time of PCA manufacture to support either RS-232, RS-422 or RS-485.

Related Documents

Publications

A complete range of technical information is available to support your operation and maintenance needs. The technical publications index allows you to identify the most current version of a publication, service bulletin or related document by part number, equipment type, system and similar functions. To search the index, use the global search box in the upper right corner of the page. If necessary, click the Pubs and Training tab to see results from the technical publications index.

You can also continue to use our legacy index.

Authorized users of the technical publications index can also view all of their pubs on our dashboard. Just log in, then move your mouse over the My Account menu button and choose Dashboard.

Services & Support

Field Support Services

We provide a dedicated team of trained field service engineers ready to be dispatched at the point of need. Whether it's training, testing or on-site consultations, we have field service engineers ready to respond to your support requirements.

Contact a representative

Tailored Services

Our facilities and capabilities allow us to offer a variety of support solutions from time and material repairs to fully integrated performance based logistics via both Contractor Logistics Support (CLS) and Public Private Partnerships (PPP). The end result is increased operational readiness for the warfighter.

Our Performance Based Logistics (PBL) delivers the best combination of commercial best practices with proven logistics expertise to support challenging and ever-changing military operational requirements. PBL solutions ensure guaranteed performance for the warfighter and predictable maintenance costs.

Contact a representative

Maintenance & Repair

We actively seek to collaborate with industry and the government to implement total lifecycle support solutions within maintenance depots. By working together, efficiencies are gained that increase operational readiness, reduce total ownership costs, and reduce obsolescence exposure for the supported weapon systems. Contact a representative

Maintenance and repair are vital to support the life of your products and superior support is what we do best. Our global repair facilities provide maintenance on your equipment both in and out of warranty.  Our Equipment Repair Directory allows you to enter your part number to find locations where it can be serviced.

Spares & Parts

Our world-wide Rental/Exchange Service is ready to provide for your operational needs—24 hours a day, 7 days a week. We offer an extensive asset inventory and support system to deploy parts where and when you need them.

Phone: 1-800-713-7693 (within the U.S. only) or 1-319-295-4361
Fax: 1-319-295-6646
Email: rentalexchange@rockwellcollins.com

View our Rental and Exchange Catalog. Registration is required. 

Upgrades

We are committed to the life-cycle of your system from design and development through the long-term operational sustainment. Advancements of new technologies are something we are continuously looking at to provide additional value to our customers.