CareersNewsEvents
Home Our CompanyProducts And SystemsService And SupportInvestor RelationsContact Us
  Home > Product Catalog > Government > MDM 2x02N
 printable view
Browse by:

Search by:
    Product Index
Product Catalog - Government
Air Transport  | Business and Regional  | Government  | Service and Support

MDM 2x02N
Advanced Tactical Data Link Modem

KEY FEATURES/USER BENEFITS
Link 11 / Link 22 Modems



DESCRIPTION

Rockwell Collins MDM-2X02N is an advanced tactical data link modem which combines all functionalities required for a Link 11 Data Terminal Set (DTS) and for a Link 22 Signal Processor Controller (SPC) into a single product. TheMDM-2X02N can be provided as simple L11 DTS, single or dual-channel L22 SPC or L11/L22 modems.

The MDM-2X02N data link modem family offers three equipment versions specifically designed for airborne, ground and ship borne applications.

The MDM-2X02N product line family includes:

  • MDM-2402N: a VME type card set
  • MDM-2002N: a 19" standard rack
  • MDM-2202N: a 1/4 ATR standard chassis

All versions can be upgraded with L22 or L11 modem functions by loading SW.


CONFIGURABILITY

Depending on the configuration, several functionalities are possible. One MDM-2X02N allows:

  • Simultaneous handling of two links among the four Link 22 HF-FF, HF-EPM, UHF-FF, and UHF-EPM channels
  • Simultaneous handling of one link among the four Link 22 HF-FF, HF-EPM, UHF-FF, and UHF-EPM channels and one link among the two Link 11 HF-FF, UHF-FF channels.

These configurations can be set up via the front panel or via the remote control interface.


CAPABILITIES

Link 22 SPC

The MDM-2X02N implements the Link 22 Signal Processor Controller (SPC) functions. When configured as a full SPC, the MDM-2X02N can manage two L22 channels. For a full Link 22 configuration, two MDM-2X02 units will operate simultaneously on the four channels. Its front panel as well as its remote control interface, provide data on Link22 network status, errors detected.

Platforms operating on two Link 22 channels will only require one MDM-2X02N unit.

Link 22 system architecture



Link 22 Systems Standards Link 22 Documents 
SPC - HF FF (Fixed Frequency) STANAG 4285 / STANAG 4539 annex D 
SCCI/SP/L22/3.0
SCCI/SP/LLC-IDD/3.0
SCCI/SP/HFFFSPC/3.0
 
SPC - HF EPM STANAG 4444 
SCCI/SP/L22/3.0
SCCI/SP/LLC-IDD/3.0
TSD for NILE in HF EPM
 
SPC - UHFFF (Fixed Frequency) STANAG 4205 
SCCI/SP/L22
SCCI/SP/LLC-IDD/3.0
SCCI/SP/UHFFFSPC/3.2
 
SPC - UHF EPM STANAG 4372 
SCCI/SP/L22/3.1
SCCI/SP/LLC-IDD/3.4
UHF EPM SPC/2.2
 

Link 11 DTS

  • Operational applications
    • Station modes Net Control Station (NCS) or
    • Participating Unit (PU) per MIL-STD-188-203-1A
  • Operational modes
    • Roll call
    • Short Broadcast
    • Long Broadcast
    • Net Test
    • Net Synchronization
    • Radio Silence per MIL-STD-188-203-1A
  • Modem waveforms
    • CLEW (Conventional Link Eleven Waveform) per MIL-STD-188-203-1A
    • Doppler frequency shift correction: +75Hz, tracking at 3.5Hz/sec on 605Hz pilot tone
    • Independent sideband operation (diversity)
    • SLEW (Single-tone Link Eleven Waveform) per SPAWAR-S-850 dated 10 February 1992
  • SATCOM L11 Interface
    • In addition to the audio interface to the HF or UHF radios, the MDM-2x02N offers and RS-232 interface to exchange Link 11 over a SATCOM network
  • Dual Link 11 capability
    • The MDM-2x02N supports network management and data transmission over one Link 11 network using simultaneous operation

Local/Remote Control Interface

The MDM-2X02N may be controlled either locally from the front panel or remotely (RS-232 compatible) via its control interface. Control software for Windows® 2000/NT operating system PC compatible computers is available.

Link 11 Split Site Capability

To support Link 11 installations where the Tactical Data System (TDS) computer and the radio equipment are located at separate sites, the MDM-2002N has a split site interface and supporting features. One MDM-2002N is to be installed on each site and interconnected by a digital link which may be used to pass tactical data and control information between both MDM-2002N units.

Comprehensive Built-In-Test

Modem operation and maintenance are enhanced by built-in automatic performance monitoring and fault isolation circuits. When primary power is first applied, a self-test is automatically initiated to verify operational status of the modem. During operation, the processors continue to perform background diagnostics. Self-test can also be initiated via the local/remote control interface. Detected faults are identified at the front panel and in subsequent status messages output at the control interface.


Interfaces 
 MDM-2x02N 
Link-11 Tactical Data System Computer Interface 
NTDS (parallel) per Appendix D1 or MIL-STD-188-303-1A or ATDS (serial) per Appendix D2 of MIL-STD-188-203-1A
 
LLC/SNC/TDS Computer Interface 2 RS-422 interfaces 
Audio Interface  Two dual 0 ohm, 600 ohm transformer coupled transmit and receive interfaces 
SATCOM Interface RS-232, synchronous, 2400 bit/sec 
Keyline 
3 outputs:- open collector output- 6 volt logic output- 6 VDC on transmit audio
 
Split-site interface 
Two RS-232 ports, asynchronous, 4800 or 9600 bit/sec
 
Data UHF 
Two WB audio (11 Khz)
 
TOD source 
Havequick TTL
 
Radio Control 
Two RS-232 interfaces
 
Control Interface 
RS-232 compatible, asynchronous, 4800 bits/sec (L11) , 19200 bits/sec (L11-L22) or 1553B bus interface
 
Software download interface 
RS-232 , 115200 bits/sec
 

Reliability (MTBF) 
Ground Fixed (GF) 15,000 hours, at 30°C per MIL-HDBK-217E 
Airborne Inhabited Cargo (AIC) 12,000 hours, at 25°C per MIL-HDBK-217E 
Airborne Rotary Wing (ARW) 5,000 hours, at 40°C per MIL-HDBK-217E 
Link 11 system architecture


The interface towards the crypto module can be either NTDS (MDM-2002N or MDM-2402N), or ATDS.

In addition to the audio interface to the HF or UHF radios, the MDM-2X02N offers an RS-232 interface to exchange Link 11 over a SATCOM network.

The MDM-2X02N supports network management and data transmission over one Link 11 network using simultaneous operation.


MDM 2x02N Operational Applications 
Station modes Net Control Station (NCS) or Participating Unit (PU) as per MIL-STD-188-203-1A 
Operating modes 
Roll Call, Short Broadcast, Long Broadcast,
Net Test, Net , Radio Silence as per MIL-STD-188-203 -1A
Rockwell Collins defined Link Test
 

MDM 2x02N Modem Waveforms 
CLEW (Convention Link Eleven Waveform) Per MIL-STD-188-203-1A Doppler frequency shift correction ±75 Hz, tracking at 3.5 Hz/sec on 605 Hz pilot tone Independent sideband operation (diversity)  
SLEW (Single-tone Link Eleven Waveform) Per SPAWAR-S-850 dated 10 February 1992 

SPECIFICATIONS

Physical Characteristics 
Weight 
VME type card set3.5 lb (1.6kg)19" standard rack13lb (5.9kg)1/4 ATR standard chassis9 lb (4.5kg)
 
Size/Dimensions 
VME type card set6U, 2 slots VME module19" standard rack3.5in H x 18in W x 10.8in D (89cm H x 483cm W x 275cm D)1/4 ATR standard chassis5.8in H x 2.3in W x 13.15in D (19.81cm H x 5.84cm W x 33.38cm D)
 

Power Supply 
MDM-20002/NPower Consumption
 
90-264 VAC 47-440Hz30 W max
 
MDM-2202/NPower Consumption
 
28VDC per MIL-STD-704D30 W max
 

Description/CPN L11 Capability L22 Capability 
MDM-2002/N (NTDS)
822-0307-301 
Kit Upgrade 
MDM-2002/N (ATDS)
822-0307-201 
Kit Upgrade 
MDM-2402/N (NTDS)
822-0753-301 
Kit Upgrade 
MDM-2402/N (ATDS)
822-0753-201 
Kit Upgrade 
MDM-2202/N (controlled via serial IF)
822-0025-201 
Kit Upgrade 
MDM-2202/N (controlled via MIL-STD-1553B IF)
822-0025-101 
Kit Upgrade 
MDM-2002/N (NTDS)
822-0307-351 
Kit Upgrade 
MDM-2002/N (ATDS)
822-0307-251 
Kit Upgrade 
MDM-2402/N (NTDS)
822-0753-351 
Kit Upgrade 
MDM-2402/N (ATDS)
822-0753-251 
Kit Upgrade 
MDM-2202/N (controlled via serial IF)
822-0025-251 
Kit Upgrade 
MDM-2202/N (controlled via MIL-STD-1553B IF)
822-0025-151 
Kit Upgrade 

Link 11 kits are also available for all L22 modems.


Description CPN 
L22 kit for MDM-2002/N 222-3032-512 
L22 kit for MDM-2402/N 222-3032-513 
L22 kit for MDM-2202/N 222-3032-514 (serial)222-3032-518 (MIL-STD-1553B) 

TBMDM-2X02 TEST SET

The TBMDM-2X02 test set is dedicated to the MDM-2X02N modem maintenance. It enables the connection with the following modem versions:

  • MDM-2402N ATDS and NTDS: VME version,
  • MDM-2002N ATDS and NTDS: rack 19 with control panel,
  • MDM-2202N Aiborne version (cylindric connectors).

The test procedure consists in activating an MDM-2X02N integrated test either with an external "strap" (for the MDM-2402N version) or a "dip switches" configuration (for the MDM-2202N version). Error detection for board failure is correlated with the total number of impulses received matching a dedicated code. Additional testing is done to determine both audio (power supply and form) and ATDS (power supply and pulse bandwidth) signal features.

Test set for LInk 11 / Link 22 Modems